Specifications

Advance Settings for the v9S Single Com Port System
Advance Encoder Settings
To enter the “Advanced Encoder Settings” Screen you must type in the User ID “Maint” (Not Case Sensitive).
Click “OK”. See Fig. 15A
Fig. 15A (Enter Password “Maint”)
Below is the Advanced Encoder Settings Screen.
In MOST cases you will NOT have to adjust these settings.
The “Restore Defaults” Button will set each field back to the original default settings and affects the Entire screen.
When finished, Click “OK”. See Fig. 16A
Fig. 16A (Default Settings) For the
SPS-5 v9S Single Com Port Settings Screen
Advance Encoder Settings “Default Settings: (As Shown) Fig. 16A
A: Carrier Detect = 0v
B: Transmitter Duty Cycle = 66% and Carrier Signal Detection is “ON” (Checked)
C: Data Encoding Polarity = Normal
D: Max Messages per Batch = 10 and Increment Cap Codes by 8 is “OFF” (Not Checked)
E: Settings for Com Port = Serial Port RESET of Timed Paging (Checked) and
Flow Control- Setting = Hardware (RTS/CTS)
F: Restore Defaults- This Button will set the Entire Screen to Original Factory Default Settings.
G: Paging Site License Call Sign- Station ID Information - Sent in Morse Code approx. every 30 Seconds
For Programming/Reading/Saving the Database and Settings: (See Next Page).