User's Manual
USER MANUAL – ActivDuo Active RFID Tags
Configuration No. Wavetrend Technologies Ltd Master File Name Issue Date Page
00000-0000-150-1 User Manual ActivDuo Tag-00.8-UM-LT 3 DECEMBER 2008 11 OF 42
1.4 Standard Tag Functionality
The ActivDuo tag offers three primary modes of operation that determines how often the tag will transmit.
They are defined as being ‘Standard’, ‘Movement Alert’ and ‘Tamper Alert’ transmission modes:
1.4.1 Standard Transmission Mode
In this mode, the tag will transmit its ID number and
ancillary data regularly at the programmed status
transmission interval (called the ‘Status Tx rate’).
The default Status Tx rate is 1 transmission at least
every 10 seconds. Other transmission intervals for the
Status Tx rate greater than 10 seconds can be selected
by the user and programmed into the tag through a tag
programmer unit. See the section on tag programming
for more information on how to do this.
1.4.2 Movement Alert Mode
In this mode the tag will transmit its data at a shorter
alert interval (the ‘Alert Tx rate’) for a short period of
time if the motion sensor within the tag registers
movement or vibration.
For L-Series and W-Series, the default transmission
rate for movement alert operation is 1 transmission
every 1.5 seconds. But other alert transmission
intervals (0.4 or 0.8 seconds for L-Series and 0.4 / 0.8 /
1 / 3 or 5 seconds for W-Series) can be selected by the
user and programmed into the tag.
The tag will cease transmitting at the Alert Tx rate after
5 seconds of entering Movement Alert mode and revert
to the Status Tx rate. Each time the motion sensor is
activated when the tag is in Standard mode, the tag will
immediately enter the Movement Alert mode.
The movement counter will increment each time the
Movement Alert mode is activated.
1.4.3 Tamper Alert Mode
In this mode, triggered by the anti-tamper circuit, the
tag will transmit its data, together with setting the Alarm
bit, in a rapid burst of four alert transmissions and in
intervals of 0.4 seconds. The tamper alert mode will interrupt the movement alert mode if a tamper
event occurs while the tag is moving. The tamper counter value will increment each time the Tamper
Alert mode is activated.
1.4.4 Manual Alert Operation for the TG700-A Key Fob PA Tag
The Key Fob PA tag does not include a motion sensor. In its place a push button is fitted. When
pressed, the push button activates the Movement Alert mode of operation. The alert transmissions
Alert Tx Rates
L Series
Status Tx Rates
L-Series
0.4 seconds
10 seconds
(default)
0.8 seconds
30 seconds
1.5 seconds
(default)
Table 3 - List of Programmable Nominal
Transmission Rates for the L-Series ActivDuo
tags
Alert Tx Rates
W Series
Status Tx Rates
W-Series
0.4 seconds
10 seconds
(default)
0.8 seconds
15 seconds
1 second 20 seconds
1.5 seconds
(default)
30 seconds
2 seconds 45 seconds
5 seconds 1 minute
- 1.5 minutes
- 2 minutes
- 3 minutes
- 5 minutes
- 10 minutes
Table 4 - List of Programmable Nominal
Transmission Rates for the W-Series ActivDuo
tags