Operation
Once the unit is calibrated, it is ready for operation. Service the chemical and solvent tanks.
See Fig.7 and note the valve positions for chemical and solvent. Set the valve to the proper
position. Be sure that the "butterfly vent" on the motor side of the cabinet is open.
Start the vehicle, and turn on the Unit switch at the control box. Momentarily turn on the
Pump switch and check the red indicator light at the control box. It should come on. If it does not,
turn all switches off and visually check that the pressure switch wire is installed to the Normally
"OPEN" position (see Fig. 5).
Droplet Median Diameter Measurement of the Mozzie Electric Fog
Determination of median droplet size on the Mozzie Fog can be affected by both the method
of collection and the conditions under which the test is performed. These instructions are provided
as a general guide to aid the user in obtaining the most accurate results. As a rule this test
recommendation is applicable to both the Mozzie Electric and the Mozzie Gas Fogger and, in
addition, is based upon familiarity with the KLD Labs DC-III ™ and the label instructions of Aqua-
Reslin
®
.
Begin by positioning the equipment where any existing wind is downstream from the nozzle.
If at all possible, locate the unit in a closed structure with one side open where the insecticide cloud
INSECTICIDE
SOLVENT
VALVE LOCATION