Use a small load electric drill or light to plug into the inverter. The drill or light should run
normally. Turn the unit switch on the control box off. The green light on the inverter will slowly fade
until completely off. Now reconnect the blower. With the unit completely connected, start the vehicle
and run at idle. Turn the Unit switch on the control box to the "ON" position. With a DC multimeter
check the voltage across the battery terminals of the unit. You should read 12.5-12.7 + volts on the
meter. If available, check the current draw with a clamp-on ammeter capable of reading AC/DC true
RMS such as a Wavetek AD105 Cat.III 1000 Amp. You should obtain a reading of 87-90 Amps.
Calibration - Model 200
The pump was calibrated at the factory to dispense 4 oz/minute of mineral oil. Due to
voltage variations from vehicle to vehicle, a slight adjustment at the pump control may be needed to
fine tune the chemical system for proper flow rate. To adjust the flow rate, be sure that the Mozzie
Electric Fog is connected to the vehicle charging system. Fill the chemical tank about half full of the
chemical to be used. Disconnect the chemical line at the nozzle and place in a suitable container or
route back to the tank. See p.8 to set the proper valve position. Turn the pump switch ON and
allow the system to fill with fluid. Run the pump until all air is purged from the pump and valve. When
all air has been removed, transfer the fluid line into a graduated cylinder and measure the fluid flow
for two minutes. Set the approximate desired flow rate of the pump by referring to the table:
Pump Setting Rate OPM
1.25 2
2.2 4
3.15 6
4 8.45
With the pump set, reconnect the insecticide line to the nozzle.
Pump set at 1.2