MOZZIE ELECTRIC FOG OWNER'S MANUAL MODELS 200-250 55-73-0200 © 2004 ARRO-GUN SPRAY SYSTEMS 040505
TABLE OF CONTENTS PAGE Specifications Setup Electrical Test 3 3-4 5 Calibration 6-7 Operation 7-8 Droplet Median Diameter Measurement 8-9 Maintenance Parts How to Order Parts 9 10-16 16
Specifications - Model 200 Dimensions Weight Cemical Tank Pump Pump Flow Rate Voltage Full Load Amperage Recommended Battery Recommended Alternator 42" W x 21"D x 40" H 107cm W x 53cm D x 102 cm H Net: Gross: Net: Gross: 4 Gallon Max Capacity HDPE 12 VDC FMI Type RHB 8.5 OPM Max, 1 - 6 OPM Recommended 12 Volts DC Nominal, 12.5 - 13.
Setup Packed in the cabinet are the control box, nozzle(s) with quick couplings, a main power cable, ground cable, and high output alternator (if supplied) as required for the vehicle the unit will be mounted to. Have the alternator installed to the vehicle by a qualified mechanic. Position the unit to the truck bed and if desired, bolt the skids to the truck or secure by other means.
IMPORTANT: BEFORE THE UNIT IS OPERATED FOR THE FIRST TIME THE BATTERY MUST BE FULLY CHARGED. PLACE THE BATTERY ON A MINIMUM 6-10 AMP CHARGER CAPABLE OF TRICKLE CHARGE MAINTENANCE AND CHARGE A MINIMUM OF 12 HOURS. DO NOT USE THE VEHICLE ALTERNATOR TO CHARGE A LOW BATTERY. Battery Alternator MODEL 250 12 Vdc~115 Vac B+ BATT + Unit Battery Main Cable 200 A Contactor Fig. 3 Blower Inverter Electrical Test - Model 200 With the unit completely connected, start the vehicle and run at idle.
Use a small load electric drill or light to plug into the inverter. The drill or light should run normally. Turn the unit switch on the control box off. The green light on the inverter will slowly fade until completely off. Now reconnect the blower. With the unit completely connected, start the vehicle and run at idle. Turn the Unit switch on the control box to the "ON" position. With a DC multimeter check the voltage across the battery terminals of the unit. You should read 12.5-12.
Calibration - Model 250 Model 250 is equipped with a pressure switch located at the top of the motor unit just behind the air outlet. The pressure switch controls the chemical pump by switching the pump on only if there is sufficient air pressure on the air manifold. The unit is shipped with the wire tab attached to Normally OPEN COMMON Normally CLOSED Fig.5 the Normally OPEN connection at the pressure switch. Temporarily move the wire tab to the Normally CLOSED connection.
VALVE LOCATION INSECTICIDE SOLVENT Fig. 7 Operation Once the unit is calibrated, it is ready for operation. Service the chemical and solvent tanks. See Fig.7 and note the valve positions for chemical and solvent. Set the valve to the proper position. Be sure that the "butterfly vent" on the motor side of the cabinet is open. Start the vehicle, and turn on the Unit switch at the control box. Momentarily turn on the Pump switch and check the red indicator light at the control box. It should come on.
will exhaust outdoors. Mix the Aqua-Reslin in the ratio planned for treatment, and place in insecticide tank. Operate the unit and, with a anemometer, find the point at which the nozzle velocity reads 33.5 meters/second (on the Mozzie Electric this is approximately 36"-42" from the nozzle).
Parts 1 2 3 4 5 10 9 6 7 8 Key Part No. 1 55-70-0255 Contactor, 200 Amp 1 1/4-20 X 3/4 H.H. Capscrew 18-8 SS 2 Nylock Nut 18-8 SS 2 SAE Washer 18-8 SS 4 Terminal Block 1 Socket Hd Capscrew 18-8 SS 2 #10 SAE Washer 18-8 SS 2 #10 Split Lockwasher 18-8 SS 2 Chemical Pump, HO 1 1/4-20 1/4 2 55-70-0205 10-32 X 1 3 55-70-0619 55-70-0132 Description o 1/4 NPT 90 Swivel o Qty 1 55-70-0240 90 Filter Elbow 2 55-70-0239 Filter Adapter 1 1/4-20 X 3/4 H.H.
4 5 55-70-0217 Filter, 80 Mesh 1 55-70-0238 Filter Connector 1 55-70-0211 3-way Valve 1 55-70-0132 o 1/4 NPT 90 Swivel 3 1/4-20 X 7/8 H.H. Capscrew 18-8 SS 2 Nylock Nut 18-8 SS 2 1/4 SAE Washer 18-8 SS 2 55-70-0266 Chemical Tank, 6 Gal. 1 Cap, Chemical Tank 1 55-70-0232 4 Gal.
10 55-70-0214 Prestolok Bulkhead 1 55-70-0236 Sealing Washer 2 2 1 3 4 Key Part No. 1 55-70-0310 2-Pin Connector Set, Fanged 1 2 55-70-0613 Receptacle 1 Dust Cap w/Chain 1 Pan Hd MS 18-8 SS 4 Hex Nut 18-8 SS 4 #4 Split Lockwasher 18-8 SS 4 #6 Sae Washer 18-8 SS 1 55-70-0206 Single Pole Socket 1 1/4-20 X 7/8 H.H.
2 3 1 4 5 8 6 7 Key Part No.
Key Part No. 4 55-70-0281 1/8 NPT X 1/4 Tube Prestolok 3 5 55-70-0282 Prestolok 1/4 Union Tee 1 6 55-70-0178 Adapter 1-1/2 MPT X Sanitary 2 7 55-70-0124 PT-150 Aluminum Plug 2 55-70-0125 PT-150A Aluminum Adapter 2 55-70-0126 Coupler 2 55-70-0180 Clamp, Single Pin 4 55-70-0181 Viton Gasket 4 8 Description Qty 1 2 4 3 Key Part No.
Key Part No. 3 (cont.) 10-32 4 15 Qty Description Nylock Nut 4 55-70-0251 Blower Housing 1 55-70-0256 Shock Mount 6 1/4-20 X 5/8 Hex Hd Capscrew 18-8 SS 6 1/4 SAE Washer 12 1/4 Split Lockwasher 6 Nylock Nut 4 1/4-20 1 3 2 Key Part No.
Key Part No. NA 55-74-0250 Description Qty Control Box Assy (Not shown) 1 6 1 5 2 3 4 Key Part No.
How to Order Parts Parts are available from Arro-Gun Spray Systems by contacting the toll free factory number: Arro-Gun Spray Systems, LLC 7575 Tamra Drive Reno, Nevada 89506 Phone: 775-972-4782 (Cell 775-843-2647) (Factory Toll Free) 1-888-277-6486 Please have available the serial number of the unit requiring replacement parts.