Specifications
User Manual 301/302 
VOLTage? 
Response 
The 302 will return the present amplitude value. The returned value will be in standard scientific format (for 
example: 100mV would be returned as 100E-3 – positive numbers are unsigned). 
  VOLTage:OFFSet <offs> 
Purpose 
This command programs the amplitude offset of the output waveform. The offset is calibrated when the 
source impedance is 50Ω. 
•  <offs> numeric value that sets the amplitude offset 
 VOLTage:OFFSet ? 
Response 
The 302 will return the present offset value. The returned value will be in standard scientific format (for 
example: 100mV would be returned as 100E-3 – positive numbers are unsigned). 
  SINusoid:PHASe <phase> 
Purpose 
This command programs start phase of the standard sine waveform. This command has no affect on 
arbitrary waveforms. 
•  <phase> numeric value that sets the start phase 
SINusoid:PHASe? 
Response 
The 302 will return the present start phase value. 
  TRIangle:PHASe <phase> 
Purpose 
This command programs start phase of the standard triangular waveform. This command has no affect on 
arbitrary waveforms. 
•  <phase> numeric value that sets the start phase 
TRIangle:PHASe? 
Response 
The 302 will return the present start phase value. 
  SQUare:DCYCle <duty_cycle> 
Purpose 
This command programs duty cycle of the standard square waveform. This command has no affect on 
arbitrary waveforms. 
•  <duty_cycle> numeric value that sets the duty cycle value 
SCPI Command Reference 