User's Manual

Release Notes Document
PDU Display Garbage Page 7 of 8
3. TESTING SCOPE
3.1 Test Environment:
EQ set-up for 4 counters, with following configuration:
2 Bar SDU, in Dual-Line mode Powered by 5V Adaptor
1 Cube SDU Powered by 5V Adaptor
3 CDU Powered by Active Hub
1 PDU Powered by Active Hub
1 TDU-Lite Powered by 12V Adaptor
2 Hard-TSU Powered by Active Hub
1 Soft-TSU Powered by Active Hub
Configuration Description:
PDU acts as CDU
Bar SDU, Cube SDU and CDU connected with 1 separate Active Hub, with 12V input
power supply.
Hard TSU and TDU-Lite connected with 1 separate Active Hub, with 12V input power
supply.
PDU connected with 1 separate Active Hub, with 5V input power supply.
3.2 Test cases & Result:
S.No.
Test case
No. of
Cycles
Test Result/Output
1
Display on PDU, without any corrupted
image?
100
100/100 - Passed
2
All CDUs, PDU & SDUs updated every
time & correctly?
100
100/100 Passed
3
Calling sound always synced with calling?
100
100/100 Passed
4
Ticket issuance from TDU Lite
100
100/100 Passed