Above mentioned IDs number “START ID” and “END ID” is to scan number of TSUs connected with Active Hub, in
above scenario Scan ids for TSU`s goes from 0 to 22.
We need to change “END ID” by pressing button “0” to decrease number of TSUs IDS and press button “7” to
increase the number of TSUs IDS of TSU. In our case we need to change “END ID” to 16 because only 16 ports are
available on the Active Hub.
However, we can increase number of ports of Active Hub. We are testing Active Hub with only one TSU. Connect
TSU with the port 1 on Active Hub, as shown in following diagram:
Connect TSU with ID 1 to port 1 on active hub; for ID change follow the procedure of section VIII and press
Next/OK on network scanner TSU to test Active Hub, following message will appear:
START ID = 01
6-UP 9-DOWN
END ID = 22
7-UP 0-DOWN
NEXT/OK TO SCAN
RJ45–RJ45 Cable (Connect from scanner PCB to
Active Hub “IN” Port)
RJ12–RJ12 Cable (Connect from Network scanner
PCB to TSU)
RJ45-RJ12 Cable (Connect from Active Hub Port to
TSU