3.2 Absolute Minimum and Maximum Ratings
Table 3-2: Minimum and Maximum Ratings
3.3 Operating Range
Table 3-3: Operating Range
3.4 Electrical Specifications
Table 3-4, “Performances,” on page 13 summarizes the electrical performance of the SX1302, over operating conditions.
The reference design described in Section 10. "Application Information" on page 24 is used to measure this performance.
Symbol Description Min Max Unit
V
CCIO,ABSMAX
IO power supply to VSS -0.5 4.0 V
V
CCcore,ABSMAX
Core power supply to VSS -0.5 1.5 V
T
STORE
Storage temperature -40 +125 °C
T
REFLOW
Peak reflow temperature 260 °C
MSL Humidity rating MSL1
Symbol Description Minimum Typical Maximum Unit
V
CCIO,OP
IO supply operating conditions 3.0 3.3 3.6 V
V
CCCORE,OP
Core supply operating
conditions
1.1 1.2 1.3 V
T
A,OP
Operating temperature -40 25 +85 °C
Table 3-4: Performances
Symbol Description Min Typ Max Unit
IDD_8CH_CO
RE
Average consumption when all correlators are active
(no packet detected, no modem activated), on VCC_CORE
-15-mA
IDD_8CH_IO
Average consumption when all correlators are active
(no packet detected, no modem activated), on VCC_IO
-1-mA
IDD_8CH_AV
G_CORE
Average consumption when all correlators are active, and 16 modems are
active, on VCC_CORE
-1777mA
IDD_8CH_PE
AK_CORE
Peak
1
consumption when all correlators are active, and 16 modems are active,
on VCC_CORE
-2885mA
IDD_8CH_AV
G_IO
Average consumption when all correlators are active, and 16 modems are
active, on VCC_IO
-1-mA