3. Specifications
All measured performances and conditions are listed in this chapter. Quantitative indications left in other chapters are for
the ease of reading and are indicative only.
The following specifications are given for the typical operating conditions of VCC_IO = VBAT = 3.3V, temperature = 25 °C
(85°C for maximum values), reference oscillator frequency = 32 MHz, RF centre frequency = 868 MHz. All RF impedances are
matched using the reference design, see Section 10.2 "Reference Block Diagram" on page 24. Blocking, ACR and co-channel
rejection are given for a single tone interferer and referenced to sensitivity level +6dB.
3.1 ESD Notice
The SX1302 has built-in ESD and latch-up protection.
It should however be handled with all the necessary ESD precautions to avoid any permanent damage.
Table 3-1: ESD and Latch-Up Notice
Symbol Description Min Typ Max Unit
ESD_HBM
Class 2 of ANSI/ESDA/JEDEC Standard JS-001-2014
(Human Body Model)
--2 kV
ESD_CDM
ESD Charged Device Model, JEDEC standard
JESD22-C101, class C4
- - 500 V
LU Latch-up, JEDEC standard JESD78 B, class I level A - - 100 mA