Data Sheet
9/24/2015 ARPI600WaveshareWiki
http://www.waveshare.com/wiki/ARPI600 9/18
2. Select the option ZIBGEE ROUTER/END DEVICE AT under the pull‐down menu Function Set:
Selecting the option ZIBGEE ROUTER/END DEVICE AT under Function Set
3. Set the read Networking parameters:
ID: 234
DH: 0
DL: 0
4. Click the button Write to download the configured parameters into the XBee‐A module.
Configuring XBee‐B module
1. Configure XBee‐B module according to the processes described in the Section 3.1 and the
Section 0. However, there is something different. In configuring XBee‐B, you should select
the option ZIBGEE COORDINATOR AT under the pull‐down menu Function Set:
Selecting the option ZIBGEE COORDINATOR AT under Function Set
2. Set the read Networking parameters:
ID: 234
DH: 0
DL: ffff
3. Click the button Write to download the configured parameters into the XBee‐B module.
4. In order to implement a simple P2P network, please configure XBee‐A and XBee‐B according
to the processes described above. Start two X‐CTU tools, and select different COM interfaces
in the option PC Settings to control Group A and Group B respectively.
5. Input the data to be transmitted in the X‐CTU Terminal of XBee‐A, then, you can find that
the inputted data will be sent to XBee‐B automatically, and displayed in the X‐CTU Terminal
of XBee‐B. In the X‐CTU, data in blue is the data to be sent, and data in red is the received
data.
Data transmission and receive