Data Sheet
Product Specification 
Ver 1.2                                                                                            40 / 43 
11. Reliability test 
  TEST  CONDITION  METHOD  REMARK 
1 
High-Temperatu
re Operation 
T =40℃, 
RH=35% for 240 
hrs 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be  taken  out  from  the  high 
temperature environmental chamber and set aside for a few 
minutes. As EPDs return to room temperature, testers will 
observe  the  appearance,  and  test  electrical  and  optical 
performance based on standard # IEC 60068-2-2Bp. 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
performance 
standards. 
2 
Low-Temperatu
re Operation 
T = 0℃ for 240 
hrs 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be  taken  out  from  the  low 
temperature environmental chamber and set aside for a few 
minutes.  As  EPDs  return  room  temperature,  testers  will 
observe  the  appearance,  and  test  electrical  and  optical 
performance based on standard # IEC 60068-2-2Ab. 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
performance 
standards. 
3 
High-Temperatu
re Storage 
T = +60℃, 
RH=35%   
for 240 hrs 
Test in white 
pattern 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be  taken  out  from  the  high 
temperature environmental chamber and set aside for a few 
minutes. As EPDs return to room temperature, testers will 
observe  the  appearance,  and  test  electrical  and  optical 
performance based on standard # IEC 60068-2-2Bp. 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
performance 
standards. 
4 
Low-Temperatu
re Storage 
T = -25℃   
for 240 hrs 
Test in white 
pattern 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be  taken  out  from  the  low 
temperature environmental chamber and set aside for a few 
minutes. As EPDs return to room temperature, testers will 
observe  the  appearance,  and  test  electrical  and  optical 
performance based on standard # IEC 60068-2-2Ab. 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
performance 
standards. 
5 
High 
Temperature, 
High- 
Humidity 
Operation 
T=+40℃, 
RH=80% 
for 240 hrs 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be taken out  from the  environmental chamber and set 
aside  for  a  few  minutes.  As  EPDs  return  to  room 
temperature,  testers  will  observe  the  appearance,  and  test 
electrical and optical performance based on standard # IEC 
60068-2-3CA. 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
performance 
standards. 
6 
High 
Temperature, 
High- 
Humidity 
Storage 
T=+50℃, 
RH=80%   
for 240 hrs 
Test in white 
pattern 
When  the  experimental  cycle  finished,  the  EPD  samples 
will  be taken out  from the  environmental chamber and set 
aside  for  a  few  minutes.  As  EPDs  return  to  room 
temperature,  testers  will  observe  the  appearance,  and  test 
electrical and optical performance based on standard # IEC 
60068-2-3CA. 
When experiment 
finished, the EPD 
must meet electrical 
performance 
standards. 
7 
Temperature 
Cycle 
[-25℃  30mins]→   
[+60℃,RH=35% 
30mins], 50cycles 
Test in white 
1.  Samples are put in the Temp & Humid. Environmental 
Chamber. Temperature cycle starts with -25 , storage ℃
period 30 minutes. After 30 minutes, it needs 30min to 
let temperature rise to 60℃. After 30min, temperature 
When experiment 
finished, the EPD 
must meet electrical 
and optical 
. 
2.7" e-Paper (B)