Data Sheet
Product Specification 
Ver 1.2                                                                                           13 / 43 
(3)  Power OFF (PWR)    (R02H) 
Action  W/R  C/D  D7  D6  D5  D4  D3  D2  D1  D0 
Turning OFF the power  0  0  0  0  0  0  0  0  1  0 
After the Power Off command, the driver will power off following the Power Off Sequence.   
After the Power Off command, BUSY_N signal will drop from high to low. When finish the power off sequence, BUSY_N signal will rise 
from low to high. 
This command will turn off charge pump, T-con, source driver, gate driver, VCOM, and temperature sensor, but register data and SRAM 
data will kept until VDD OFF.   
Source Driver output and Vcom will base on previous condition, which may have 2 condition: 0V or floating. 
(4)  Power OFF Sequence Setting (R03H) 
Action  W/R  C/D  D7  D6  D5  D4  D3  D2  D1  D0 
Setting Power OFF Sequence 
0  0  0  0  0  0  0  0  1  1 
0  1  -  -  Vsh_off[1:0]  Vsl_off[1:0]  Vshr_off[1:0] 
Vshr_off[1:0]:    00: 5 ms (Default)            01: 10 ms              10: 20 ms                  11: 40 ms 
Vsl_off[1:0]:    00: 5 ms (Default)              01: 10 ms              10: 20 ms                  11: 40 ms 
Vsh_off[1:0]:    00: 5 ms (Default)            01: 10 ms              10: 20 ms                  11: 40 ms 
(5)  Power ON (R04H) 
Action  W/R  C/D  D7  D6  D5  D4  D3  D2  D1  D0 
Turnning ON the Power  0  0  0  0  0  0  0  1  0  0 
After the Power ON command, driver will power on based on the Power ON Sequence.   
After Power On command, BUSY_N signal will drop from high to low. When finishing the power off sequence, BUSY_N signal will rise 
from low to high.   
(6)  Power ON Measure (PMES)    (R05H) 
Action  W/R  C/D  D7  D6  D5  D4  D3  D2  D1  D0 
  0  0  0  0  0  0  0  1  0  1 
If user want to read temperature sensor or detect low power in power off mode, user has to send this command. After power on measure 
command, driver will switch on relevant commend with Low Power detection (R51H) and temperature measurement. (R40H). 
(7)  Booster Soft Start (BTST)    (R06H) 
Action  W/R  C/D  D7  D6  D5  D4  D3  D2  D1  D0 
Starting  data 
transmission 
0  0  0  0  0  0  0  1  1  0 
0  1  BT_PHA7  BT_PHA6  BT_PHA5  BT_PHA4  BT_PHA3  BT_PHA2  BT_PHA1  BT_PHA0 
0  1  BT_PHB7  BT_PHB6  BT_PHB5  BT_PHB4  BT_PHB3  BT_PHB2  BT_PHB1  BT_PHB0 
0  1  -  -  BT_PHC5  BT_PHC4  BT_PHC3  BT_PHC2  BT_PHC1  BT_PHC0 
BTPHA[7:6]:    Soft start period of phase A.     
00b: 10mS            01b: 20mS                10b: 30mS                11b: 100mS   
BTPHA[5:3]:    Driving strength of phase A     
000b: strength 1        001b: strength 2            010b: strength 3          011b: strength 4     
100b: strength 5        101b: strength 6            110b: strength 7            111b: strength 8 (strongest)     
BTPHA[2:0]:    Minimum OFF time setting of GDR in phase B     
. 
2.7" e-Paper (B)