Specifications
Chapter 11: Dynamics III 79
Using a Filtered Input Signal for
Side-Chain Processing with
Dynamics III
To use the filtered input signal to trigger dynamics
processing:
1 Ensure the Key Input selector is set to No Key
Input.
2 Ensure that the External Key button is disabled
(dark gray).
3 To listen to the signal that will be used to con-
trol side-chain input, click Side-Chain Listen to
enable it (highlighted).
4 To filter the side-chain input so that only spe-
cific frequencies within the input signal trigger
the plug-in, use the HF and LF controls to select
the desired frequency range.
5 Begin playback. The plug-in uses the filtered
input signal to trigger dynamics processing.
6 To fine-tune side-chain triggering, adjust the
plug-in controls.
Key Input selector
Side-Chain section
Side-Chain section