Specifications

Chapter 4: EQ III 21
Input Polarity Control
The Input Polarity button inverts the polarity of
the input signal, to help compensate for phase
anomalies occurring in multi-microphone envi-
ronments, or because of mis-wired balanced
connections.
Input and Output Meters
(7 Band EQ and 2–4 Band EQ Only)
The plasma-style Input and Output meters show
peak signal levels before and after EQ process-
ing, and indicate them as follows:
Green
Indicates nominal levels
Yellow
Indicates pre-clipping levels, starting at
–6 dB below full scale
Red
Indicates full scale levels (clipping)
When using the stereo version of EQ III, the In-
put and Output meters display the sum of the
left and right channels.
The Clip indicators at the far right of each meter
indicate clipping at the input or output stage of
the plug-in. Clip indicators can be cleared by
clicking the indicator.
EQ III EQ Band Controls
Individual EQ bands on each EQ III configura-
tion have a combination of controls.
EQ Type Selector
On the 1 Band EQ, the EQ Type selector lets you
choose any one of six available filter types:
High Pass, Notch, High Shelf, Low Shelf, Peak,
and Low Pass.
On the 7 Band EQ and the 2–4 Band EQ, the
HPF, LPF, LF, and HF sections have EQ Type se-
lectors to toggle between the two available filter
types in each section.
EQ Type Selectors