User Guide

Table Of Contents
52
Waves eMotion LV1 User Guide | Chapter 1: Setup
FOH Stage
I/O #1 SOE clock slave
I/O #2 SOE clock master
I/O #3 SOE clock slave
d. If you need to adjust preamps or otherwise configure the I/O, click the gear button beneath the icon to open the I/O
device’s control panel. The control panel of any assigned device (i.e., hardware I/O device, driver, external controller) will
open in a floating window, which can be repositioned. Up to five floating windows can be displayed simultaneously. Close
the window to close the control panel.
The SOE master can be locked to a system outside the SOE network (such as a mixing console). Use the device’s control panel
to configure its sync with the outside device or system. Even though this device is a slave to an outside source, it remains the
SOE master. Refer to the SoundGrid studio User Guide for a thorough description of system clocking. Control panels differ by
make and model of I/O.
e. I/O channels of all assigned deviceshardware and softwarewill appear in the Patch, Channel, and Mixer windows.
4.
Add or Change the Server
Servers are assigned and removed in the same manner as I/O devices. Some SoundGrid devices contain I/Os as well as a
server. Treat these devices as two separate units. One will appear in Racks A or B as an I/O under its own name. The other will
appear as SGS-1, SGS-1, etc.