User`s guide

Using the Front Panel
3–4 MS-4900, Rev. A
Choose
Operation:
Specify Setup
Press SELECT from the Specify Setup main topic. Then use the < > buttons to
access screens for the following purposes:
Change output port configuration settings
Enable or disable a screen login
Enter a password to restrict access to certain screens
Enable or disable a screen lock
Enter or change IP addresses (Ethernet model only)
CAUTION: Changes you enter on these screens are not visible to the network
operator and could be reset with a network download, possibly
interrupting site operation. It is a good idea to record (and report to
the network operator) important changes you make to parameters
onsite, in case you need to re-install those settings.
To Enable or
Disable a Screen
Login:
Enabling the login requires a user to enter a password to access any IDR V1000
screens where parameters can be modified. (The Set Features screen can still be
changed and all settings can still be viewed without entering a password.)
Use the > button to access this screen:
Press SELECT to display this screen:
1. Use the < > buttons to change from noto yes.
2. Press SELECT to set the entry.
3. Enter your password.
4. Press CANCEL twice to return to the main topics
NOTE: You must enable the screen login if you want to use the Logoff function to
turn off asynchronous data output (from the main topic Logoff).
Login Enabled:
3N Y
Specify:
Enable Login