User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Using the Modem Test Jig
- Testing
- Desense
- Application Development
- Message Routing and Migration
- Appendix A - NCL Interface
- Appendix B - Software Development Kit
- SDK Contents
- System Requirements
- SDK Software Architecture
- NCL Application Programmer’s Interface
- Implementation
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- SCR Application Programmer’s Interface
- A
- Appendix C – Sample programs
- Appendix D - Wavenet Application Loader
- Appendix E - Numeric Conversion Chart
- Appendix F - Specifications
- Appendix H - Glossary
Boomer II User Manual & Integrator’s Guide ___________________________________________ NCL INTERFACE
BM210012WT27 125 Wavenet Technology
Generic set RPM Configuration command type 2
This command allows the DTE to set the configuration settings of
certain aspects of the modem.
Command Format:
Response Syntax:
OPERAND DESCRIPTIONS AND RESPONSES:
There is currently only one such “Set configuration - type 2” command.
Parameter ID: WN_LEDS_OFF
Parameter contents: 16 bit (2 byte) field indicating a TRUE or
FALSE condition. TRUE (0x0001)
indicates the LEDs are disabled. FALSE
(0x0000) indicates normal LED
operation. The default is FALSE.
This command sets whether the modem’s LEDs are operational.
If they are disabled with this command, then they still flash on
powerup and powerdown, however they are inactive at all other
times. This mode allows the modem to conserve about a
milliamp of current, and is particularly suited for applications
where the modem LEDs are not visible to the user.
RESP Length SDU Tag VENDOR
SUCCESS
VEND_WAVENET
CMND Length SDU Tag
VENDOR
‘Z’
‘F’ ‘5’
VEND_WAVENET
‘F’
Parameter
ID
Parameter contents …