Specifications and Troubleshooting
General Specifications
Input Power
15VDC. Maximum Input
power when powered by a DC power supply is 900 mA
Output
Power
9 VDC
15VDC based on DC Power Supply
-
12 VDC when powered
by PoE. Sourcing up to 700 mA.
12V Outputs are Class 2, power-limited circuits
Reader Communications
Single Half
-
Duplex RS485 OSDP
Door Control
Switched 12V Power or 12V
Triggers
Temperature
-40° to 150.8° F (-40° to 66° C) and 85% humidity if DC Powered or
PoE powered with 250mA of sourced current.
-40° to 122° F (-40° to 50° C) if PoE powered and supplying
maximum external current.
Tamper
Accelerometer Based
Tamper
A/V
Red / Green / Blue LED bar and 4 kHz buzzer
UL294 Performance Levels
Destructive Attack: I
Line Security: I
Endurance: IV
Standby Power: I
Troubleshooting
- When device is powered, the reader board LED’s turn on
- Ensure I/O Cable pigtail has been properly screwed onto reader backplate
Bluetooth
The Fusion IP Reader can communicate with approved applications running on iOS 9.0 or later and
Android 5.0 or later.
Regulatory
EN302291, EN301489, EN300330, IP55, UL294
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. CAUTION: Any changes or modifications to this device not explicitly approved by the manufacturer could
void your authority to operate this equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent
appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.