User's Manual

February 2003
Rev. A
Page 46 of 47
10.6. Software window
10.6.1. General
The Software Window provides information of the burned Firmware, PLD and PHY SW in the unit.
Figure 10-6: Software Window in Unit Manager Tool
The information contains the following fields:
Ø Bank Type the bank type.
Ø Size the size of the image burned in the bank.
Ø Version the image version.
Ø Date the image date.
Ø Time the image time
Ø Checksum the image checksum.
Note: value of “FF” in the bank field’s means there is no software is burned in this bank.
10.6.2. Firmware Window
The Firmware Window provides the ability to burn a new firmware to one of the banks (Admin
user only). The new software should not be burned to the actual boot Bank. The actual boot bank
is displayed in the Boot Window. An alert message box is displayed if trying to burn the new
software to the actual boot bank. When submitting the burn operation, log prints are printed to the
log window and log file. When the burn is done the units resets and it is required to reconnect to it
and check that the software was burned (View the Software Window). Finally the boot bank
should be changed in the Boot Window.
Figure 10-7: Firmware Window in Unit Manager Tool