User's Manual

February 2003
Rev. A
Page 29 of 47
3.3. High performance Subscriber Unit (outdoor)
Physical Interface 2 x 10/100 Base-T (ODU)
Connector Type RJ-45
Protocol Supported IP, ICMP, ARP, TCP, UDP, DHCP, and HTTP
Packet classification Wire-speed layer 3
Output Power: (at antenna port) -6 dBm up to +18 dBm (1 dB step)
Antenna:
Integrated 13.5 dBi or 15.5 dBi
Detached See Table 4-2
Software Update Over the Air Download via TFTP
Operating Temperature -20°C - +55°C
Operating Humidity 5% - 95% non condensing (Rainproof)
Power (via indoor Outlet) 48 VDC, <10 Watt
Mechanical 7.5” x 7.5” x 2” (13.5 dBi antenna)
12” X 12” X 2” (15.5 dBi antenna)
Indoor outlet:
Interface: to AU RJ-45 + Led indication
Interface to WAN RJ-45
Mechanical 4” x 2” x 1”
AC Input Voltage 100 240 VAC, 47 63 Hz
Outdoor to Indoor Outlet CAT5 shielded cable (Up to 90 meters).