User's Manual

February 2003
Rev. A
Page 13 of 47
AU/SU - Outdoor Unit
with integral Antenna
AC/DC Power Supply
Indoor Outlet
100-240V AC
48V DC
48VDC + Ethernet
(CAT 5)
Ethernet
Data Cable
CAT5
User computer
Figure 2-2: GigAccess™ - General Installation Scheme

WARNING: It is the responsibility of the installer to insure that when using the outdoor antenna
kits in the United States (or where FCC rules apply), only those antennas certified
with the product are used. The use of any antenna other than those certified with
the product is expressly forbidden in accordance to FCC rules part 15.247 The
installer should configure the output power level of antennas, according to country
regulations and per antenna type.

3) Connect a ground cable between the Outdoor unit and an appropriate grounding point.
4) Connect the Outdoor-to-Indoor CAT5 shielded cable to the Outdoor unit and route it to the
location selected for the Indoor Outlet. Assemble the enclosed connector on the cable.
5) Mount the Indoor Outlet.
6) Connect the Outdoor-to-Indoor cable to the Indoor Outlet Radio port. (This port supplies
48 VDC in addition to the Ethernet data).
7) Connect the CAT5 Ethernet cable from the user’s network/PC to the Indoor Outlet data
port.
8) Connect the power supply to the Indoor Outlet power port.
9) Align the antenna and verify connectivity of the Outdoor as follows:
For SU check connectivity to the base controller.
For AU check connectivity to the SU management IP address.
The connectivity can be checked by using the ping instruction.