User`s guide
Total Jitter Histogram View
The Total Jitter Histogram view shows the Clock to Data measurements.
Bathtub View
The Bathtub curve shows the predicted Total jitter at a specific Bit Error Rate. Bit Error Rate is displayed
on the vertical axis and one UI is displayed on the horizontal. As jitter increases, the two lines will move
closer to each other. Random jitter affects the slope of the lines. A small change in RJ has a larger
effect on TJ than the same change in deterministic jitter. Deterministic jitter adds a constant offset and
will often appear as a "shelf" on one or both of the lines.
Summary View
Shows a textual summary of the specifications measured along with Pass/Fail indicators.
©
WAVECREST Corporation 2005
Section 4 - GigaView