Making a PCI Express 1.1 Hardware CR Measurement
Setup Directions
This tool uses the Multi-Rate Clock Recovery option. The option provides a compliant clock with
characteristics as required in the PCI Express Specification.
Connect the SIA-
3000 as shown below.
NOTE: When the SMA jumpers are installed, it is necessary to Check the "Voltage Correction" in the
EDIT|CR Config Menu (See figure below).
From the Main Menu, press "Data Standards" and "PCI Express", then choose "PCI Express 1.1
Hardware CR" to open the tool (See figure below).
Select your compliance point: Transmitter (TX Spec), Receiver (RX Spec),
TX add-in, RX add-in, TX System or RX system.
Click the Pulse Find button
to automatically set the voltage levels.
Then click the Single/Acquire button .
Several views are available once the measurement is complete.
Section 4 - GigaView
©