User`s guide
1-Sigma view
This view allows the user to see jitter modulation. It shows the 1-sigma values for many histograms.
This plot shows jitter components that are NOT correlated to the data and relates to the RJ and PJ
numbers in the Summary view. Refer to explanation of Accumulated Time Analysis for more information
on the measurement technique used to generate this plot.
If TailFit option is enabled, another line will be displayed on this plot. This line represents the RJ or RMS
jitter when there is a significant amount of PJ present. The 1-sigma values are plotted to give the user a
view of the modulation that may be causing PJ.
The x-axis shows span of accumulated edges
The y-axis shows 1-sigma
Section 4 - GigaView
©
WAVECREST Corporation 2005
138