Technical data

Seite 19
6 Technical data
Serial interfaces
- V24/RS232
- RS485 or
- CL (TTY 20mA) 2- or 4-wire - active or passive - according to EN 61107
Coverage of external devices
- + 24V / 20mA (unregulated)
- +5V / 20mA
Modem functionalilty
- Radio-Module WMOi3 or TC35 for 900/1800 MHz nets (e.g. D1, D2, E) - initial coverage 2W
- Data transmission with 9.600 Baud (V.42bis)
- Commands according to AT-Hayes
System
- RTC-real time clock with running-reserve of 35 days via Goldcap
- Processor for control (8031 Derivat)
Version
- Sealable device installation
- as field set-up housing
- on top hat rail
- on counter standard lid or
- with three-point fixing
- The terminals are suited for 2.5mm²
Housing
- Impact resistant plastic protection type IP50
- Temperature resistant up to 65° C
Operating coverage
- 90 to 260 V AC/DC, (50/60 Hz)
Line voltage
- Typically 3.5 VA. (5 VA max.)
Environmental temperature
- -10°C to +50°C
Storage temperature
- -25° C to +65° C
Humidity
- 5% to 90% R.H.(non-condensing)
Specifications / Standard
HF-irradiation:
according to IEC/EN 61000-4-3, 3V/m.
Interference immunity against electro-static discharge, ESD:
according to IEC/EN 61000-4-2, intensity grade 3.
Interference immunity against quick transient sizes, burst:
according to IEC/EN 61000-4-4, intensity grade 4.
Interference immunity against energy-strong transient sizes, Surge:
according to IEC/EN 61000-4-5, intensity grade 3
Interference transfer:
according to EN 55022/B
Net interrupt:
according to EN 61000-4-11, 100%/1s
The device corresponds to the CE regulations (EN60950, 89/336/EC, 73/23/EC)
Furthermore the indications and regulations of the Technical description for WaveCom WMOi3 and
SIEMENS TC35 are applicable.
Production according to ISO 9002
We reserve the right for technical changes.