Technical data
18
Command-Format Effect Default value
RRV
Output of the number of recall-trails in the next line.
WHAx
Selection of the radio-net
x: 0 = any operator
1,3 = operator indicated with WHI angegeben wurde
2,4 = local-net resulting from the IMSI-number
For x= 1,2 applies: if the desired net-operator does not exist/disabled, another net may
be selected. The desired net is being searched for every 14 minutes.
For x = 3,4 applies: The indicated net is logged-in exclusively.
0
RHA
Readout of the radio-net indication (see WHA)
WHIxxxxx
5-digit location-dialing code of the desired net operator (MCC + MNC) Blank
RHI
Readout of the 5-digit defined location-dialing code
RHH
Readout of the 5-digit local-net-location-dialing code of the SIM-card
RHL
Readout of the 5-digit location-dialing code of the logged-in net
WCHx
Activate RTS/CTS-Handshake at the digital trunk interface (x=1) or de-activate (x=0) 0
RCH
Reading of the Handshake settings
WDPpwd Sets a code for parameterization via a modem. The code pwd can have 6 marks at
maximum. For de-activation, WDP is transferred without pwd.
Blank
Lpwd Realizes a Login with code pwd (only necessary via modem)
SAV
Backup of the current settings on EEPROM
Q
Exits from the parameterization mode and activates the settings from the backup in
EEPROM. If there is a modem connection, the settings are only activated after hanging
up.
WPRESET
This command resets all settings (PRESET). Then, the internal RAM, the EEPROM
and the clock-module are checked. The result is delivered in decimal numbers (also see
RER-command)
BIT Information
0 no meaning
1 EEPROM-default
2 Clock-module-default
6 RAM-default – Hardware-default
NOTE!! All parameters are reset, i.e. so far parameterization loses ist effect. The
PRESET-values only become correctly active at the next net-on.
5.5.2 Messages
Default 1: invalid command
Default 2: default during backup of the parameters
Default 3: invalid code
OK: command ok