Technical data
Seite 15
5.3.2 Connect-Login-Mode
If the code for the protection against unauthorized access to the data terminals is activated,
the device is in this mode after a successful connection set up via a call. In this case the
device retransmits the signals to the calling control station
Login:
as command for entering the code.
There are 3 options to change the mode:
1. Change-over to the Connect-Transparent-Mode
If now the 8-digit code (ComuCont – ID) with closedown <CR> is transferred to the
device, this results into a change-over into the Connect-Transparent-Mode.
2. Change-over into the Connect-Parameterization-Mode
Instead of the code, you can change-over into the Connect-Parameterization-Mode via
the signal sequence $$$ (see Disconnect-Transparent-Mode). When closing down this
Mode, the device returns into the Connect-Login-Mode.
3. Starting of call-notes
When the device receives the call-note command, it hangs up automaticallly and after a
short stop starts the required recall.
Call-note command: !Sncccccccc<CR>
n: Telephon number register 0-3 of the ComuCont Dual
cccccccc: Recall recognition in case of a call to the control station
Example:
ComuCont Dual transfers: Login:
Control station transfers: !S1abcdefgh<CR>
ComuCont Dual transfers: OK <CR><LF>
(in case of a default there will be no response)
After the OK, the device hangs up and starts the recall to the telephon number from
register 1. The device returns with the text : COMUDUAL/abcdefgh
At a recall, the device is in the Connect-Transparent-Mode.
5.3.3 Connect-Transparent-Mode
This mode is reached,
- via a telephone connection by a recall (Call-note or recall automatic)
- via a telephone connection by a call, if the Transparent-Mode is not protected by a code
or
- via the Connect-Login-Mode.
In this mode, the control station can directly communicate with the terminal. Via the
sequence „$$$“ (see Disconnect-Transparent-Mode) one can change-over into the
Connect-Parameterization-Mode. However, this is only recommended with a 8.1,None
connection.
5.3.4 Connect-Parameterization-Mode / Disconnect-Parameterization-Mode
Regularly this mode is reached via the signal sequence „$$$“ (see Disconnect-Transparent-
Mode). In this mode, the following indicated commands can be transferred to the
ComuCont Dual. In case of remote parameterization, however, writing as well as reading
of the ComuCont-ID is disabled when the parameterization-code is activated. Disabling
can be opened via the command L.
Exit the mode via the command Q (see parameterization).