Technical data

14
5.2.5 Call-note
As soon as the code protection against unauthorized access to the data terminals is
activated, a call-note can be made. At the call-note, instead of the code during Login, the
command for call-note including indication of the telephon register number 0-3 of the
device, as well as a 8-digit acknowledgement recognition is transferred. Then the
ComuCont Dual automatically hangs up and, at the earliest after 5 seconds, starts the
recall to the telephon number of the selected register.
5.2.6 11bit Data transmission
Besides the standard settings of 10 bits per signal (8.1,None or 7,1,Odd) signals of 11 bits
can be transferred, too. Thus, the settings such as 8 Data, 1Stopbit and Even Parity to the
data terminal are possible. The transmission via the radio path/permanent net path is
however only possible with 10bits. Therefore reaching 11bit signals without Parity with
8.N,1 are retransmitted by the radio-module.
5.3 Working mode conditions of the device
Information on the below indicated descriptions:
Disconnect: There is no phone connection to another modem.
Connect: There is a connection to another modem.
Transparent: Data are directly (with conversion of the Baudrate and data-, Stop-, and
Paritybits) retransmitted.
Parameterize: All data are intercepted and evaluated by the processor.
5.3.1 Disconnect-Transparent-Mode
After the net-on, the ComuCont Dual is in the Disconnect-Transparent-Mode, which
means, that all signals transferred to the local digital trunk interface are automatically
retransmitted to the integrated modem of the ComuCont. In the same way, the Modem-
response is again transmitted via the interface.
Thus, the modem can be additionally parameterized with AT-commands. This function
may only be done by trained personnel!
The parameters (Baudrate, Data bits, Parity, Stopbits) of the serial digital trunk interface
can be variable adjusted (see parameterization-mode).
Note: In the Disconnect-Mode no codes are active.
Via the signal sequence $$$, which has to be entered within one second and a signal stop
of more than one second before this sequence, you get into the Disconnect-
Parameterization-Mode.