Technical data
Seite 11
4 Installation
For installation, proceed as follows:
1. Plug in the SIM-card
2. Plug in/Installation of the radio antenna
3. Plug in the serial ports to the terminal
4. Apply a voltage of (90-260 V AC/DC (50/60 Hz)
5. Parameterization of the device via the serial digital trunk interface by using the
parameterization software
NOTE: On distribution of the devices, the internal Goldcap for the coverage of the clock
module is not loaded. Therefore, time-display is lost in the case of net-off. Thus,
on distribution, the device indicates a default displayed by blinking of the two
upper diodes. Only after 5 – 15 minutes of coverage being applied upon, time
and date remain saved during a short net-off-period. After approx. 3 hours of
coverage being applied upon, the Goldcap has reached the point where tiding
over a period of 30 days is possible. If there is a lack of coverage via the
Goldcap during a net-off, the time is pre-adjusted to 00:00 o´clock on 01.01.1999
and a default is indicated. At the next net-on/off, in case that the Goldcap
meanwhile had been loaded sufficiently, the default message will be deleted.
Cancellation also results from parameterization of date or time.
NOTE: Parameterization of the device is saved on an EEPROM. If there is a lack of
coverage, this does not effect these parameters.