Specifications

VärmeKabelTeknik Switchpointheating
7
Assemblyinstruction Controlcubicle
Thecontrolcabinetshouldbemountedasclosetothe
switchaspossibletoavoidhighcostsforsuppliestothe
switchpointheatingelementsandunnecessarilylong
sensorcablescausingdeviationsinthevaluesreadoff.
Connectionstotheelementsaremadeusing8/4
conductorsinrubberwithseparateconductorsfor
each
element.
SincethecontrolcabinetisfedbyanormalEkki4/5x
6mm²itismoreeconomicaltochoosealongerdistance
fortheincomingsupply.
Thecontrolcabinetissuppliedinternallycompleted.We
supplytheconnectioncablebetweenthecabinetand
theelementinthestandardlengthof10m.Ifthe
distanceexceedsthestandardlength,anextra
connectionleadcanbejointedinajointingboxsupplied
byus.
Sensorswithcablesofrequired
lengthshouldbe
ordered.
Elementcablesshouldbeconnectedtoterminalblocks
accordingtothecircuitdiagram.
Sensorcablesareconnecteddirectlytothesensorcard.
Thecabinetsupplycabletothecabinetisconnected
directlytothelinebreakerandzero/earthterminal
block.
Sensorsaremountedontheundersideoftherailatthe
tipofthemovingrail;thesensorisfixedbytightening
theboltofthespecialfasteningdevice.Thesensor
shouldbeplacednexttoasleeperandthesensorcable
inprotectivetubingfixedtothesideof
thesleeperby
clips.
Thecontrolcabinetisconstructedaroundathyristor
controlwitheightchannels(expandable).Tothe
thyristorcontrolbelongacontrolcardandoneormore
eightchannelsensorcards.Anumberofaccessoriescan
beconnectedtothesensorcards:
Temperaturesensor(ThermoelementtypeK)
Currenttransformer
forcurrentmeasuring
Moisturesensoretc.
