Specifications

WM_PRJ_Q2501_PTS_002 - 001
March 2004
confidential ©
Page: 37 / 79
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
3.3.6 Audio interface
3.3.6.1 General
Two different microphone inputs and two different speaker outputs are
supported.
The WISMO Quik Q2501 also includes echo cancellation and noise reduction
features improving quality of hands-free function.
In some cases, ESD protection must be added on the audio interface lines.
3.3.6.2 Microphone inputs
3.3.6.2.1 General description
The difference between main microphone inputs (MIC2) and auxiliary
microphone inputs (MIC1) is the availability of an internal biasing for an electret
microphone.
For both microphone paths the connection can be either differential or single-
ended but using a differential connection in order to reject common mode noise
and TDMA noise is strongly recommended.
When using a single-ended connection, be sure to have a very good ground
plane, a very good filtering as well as shielding in order to avoid any
disturbance on the audio path.
3.3.6.2.2 Main Microphone Inputs (MIC2)
MIC2 inputs include an internal convenient biasing for an electret microphone.
This electret microphone can be directly connected on these inputs, either in
differential or single-ended mode.
AC coupling is already embedded in the module.
Pin description
Signal Pin # I/O I/O type Description
MIC2P 66 I Analog Microphone 2 positive input
MIC2N 68 I Analog Microphone 2 negative input