WAVECOM INSTRUMENTS PTY LTD© Fully Integrated TEST n PRINT UNIT User Manual TnP-500® - 10Amp Model TnP-500X® - 20Amp Model Australian Designed & Manufactured to comply with testing requirements of AS/NZS 3760:2010 Standards. Note: If required TnP Firmware can be updated by Wavecom only to comply with potential Changes in Testing Standards Head Office - Wavecom Instruments Pty Ltd Ph: (08) 8243 3500 257 Grange Road Findon SA 5023 Email: sales@wavecom.com.au Web: www.wavecom.com.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual 2
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Table of Contents Important Information Contents Precautions Manufacturer recommendations Safety Warning Fully Integrated Test n Print Unit (Diagram) Competent Person Disclaimer Limited warranty 4 4 4 4 5 6 6 6 Class 1 (Earthed Appliance) Construction Class 2 (Double Insulated) Construction Testing of Electrical Equipment To Change Test Voltage 7 7 8 9 Technical Information Integrated Tests Supply mains Test NCNT Test 9 9-10 First Te
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Important Information Contents Integrated Test N Print System User Manual WCM Keyboard Wavecom Scanner Wavecom TT Barcode Printer WinPATS Software (Full Version - Asset Management) Self Contained in Heavy Duty Case Important: IEC Test Lead (500mm Orange) USB – PC Cable Scanner Cable 2 x Rolls /500 Labels - 2 x Resin Ribbons Earth Lead with Alligator Clip (1800mm black) Locking IEC Power Cable (1800mm Blue) st Manufacturer’s 1 Calibration
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Always use specified fuses and protection devices. Do not use leads that require repair or are damaged. If you are unsure, call a licensed Engineer/Electrician. * See P.6 AS/NZ 3760:2010 def. Fully Integrated Test n Print Unit 10A ver. shown 4 5 7 Instrument description 1. Power On/Off Switch 6 2. Unit Inlet Power Socket 8 3. IEC Test Socket Appliances Test 1 4. Function Key F1 5. Function Key F2 2 12 3 6.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Competent Person To ensure that all electrical equipment or devices are inspected, tested and tagged correctly, regulations require that a ‘competent person’ such as a Licensed Electrician be employed to perform the required tests. Please refer to the above definition as described in the current AS/NZ-3760:2010 Standard and in addition, to any other local legislation or jurisdictions as may be relevant in your State.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Technical Information Class 1 (Earthed Appliance) Construction (Single basic insulated and protectively earth equipment) This type of product design provides two safety barriers between all live conductors at dangerous voltages and the equipment user. The provision of basic insulation between exposed metal parts and live parts is the first barrier to provide basic protection against electric shock.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Testing of Electrical Equipment Many testing personnel have some reservations in testing sensitive, electronic equipment using a 500V DC insulation test. There is a perceived fear of causing internal damage from over voltage. With the introduction on the TnP Range of appliance testers, these concerns are alleviated.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual To Change Test Voltage To change the test voltages select the "change ins" from the options menu. Please refer to the special functions section of this manual. Please Note: The TnP - Series will automatically default to 500VDC when restarted. Integrated Tests Supply Mains Test The Supply Mains Test checks the polarity and connectivity of the mains supply by LED's. This test is also a part of all the testing functions of this unit.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual *Optional Note: When using 3-Phase adaptors the NCNT function will need to be over ridden by pressing the ‘OK’ key prior to the TnP appliance tester performing the assigned test. Some single Phase appliances controlled by contactors will also require manual over ride. In some instances holding the ‘ON’ button will enable the NCNT function to work normally.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Powering on the Tester When the tester is powered on the scanner will beep a few times indicating the scanner is also powered. If no beep is heard check the PS2 connections from the tester. Initially the printer’s status light will be orange but after about 5-10 seconds it will change to green. The tester will not print unless the printer light is solid green. A flashing red status light can indicate a media or general printer fault.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Adding a User Screen New Barcode 0000000 5000 Users 1 - 3 Edit User X ALP Instruction From the initial screen, press F2. Don't hold the F key, this will select a different function. The TnP can hold up to 6 users. To scroll through the users, press enter. 3 sites will be shown on each screen. Each site corresponds to an "F" key, for example User 1 = F1. To edit a user, hold the corresponding "F" key for 2 seconds.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Entering Items Screen Site x New Barcode 0000000 5000 Loc | Desc | Make Location ALP Visual Check xx/xx/xxxx xx:xx Out of Services Fail Pass Main Menu A Earthed Test D/Insulated Test Lead Test (Ext Lead Test) Test Results Earthbond Pass Insulation Pass What Next? Re-Test Cont. Instruction Type in the new barcode or press F3 quickly to choose the auto generate number. Once a barcode has been specified, items can be entered.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Screen Site x Search Barcode 0000000 5000 Loc | Desc | Make Visual Check xx/xx/xxxx xx:xx Out of Services Fail Pass Main Menu A Earthed Test D/Insulated Test Lead Test (Ext Lead Test) Test Results Earthbond Pass Insulation Pass What Next? Re-Test Cont. Instruction Type in or scan the barcode number to be searched and press enter. If the screen displays new barcode press enter to switch over.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual TnP Options Menu Introduction Here you can adjust the way the TnP behaves under certain tests and other functions. Some TnP options may not available to some TnP versions. To access the TnP options menu: From either the Enter barcode screen (memory unit) or the main menu ‘A ‘ screen hold down the enter button, and then press the F2 key You should now be in the TnP options screen. The screen displays 1 option at a time.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Leakage Test Time The leakage test time is USER adjustable. You may need to adjust timing in this feature if the DUT has a long power up time or requires special power on procedure. Default time for Leakage Test is 20 seconds. From this menu you can change the test time from 5 seconds to 28800 seconds. Adjusting to any less than 5 seconds will put the test time to infinite. Press the key to increase the test time.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Choose Label Set: If you have more than one logo in the printer’s memory (multiple company logos) this function will allow you to select the various logos. If you have one logo stored in the printer then you only need to choose Label 1. If you choose anything else a blank tag will be created. If you have multiple logos then the next one to choose would be label1 and so on. If you are unsure which one to choose select the Label 0.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Other Features Barcode Printing Function - Only on Selected Memory Models This utility will print out barcode labels from what is typed on the screen. The idea is to save time by storing these barcodes in a book or collection. From here you can quickly scan a barcode without having to retype the text back into the TnP unit. To access this feature: Hold the key from the new barcode / search barcode screen.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Optional Accessories 500mm Earth Strap Part No: TnT-ES 500 3-Phase Adaptor 20A & 32A 5pin + 5pin Part No: WCM-3PH-MADP HBC Fuse Part No: WCM-HBC10AM205 Isolation Transformer for RCD testing Part No: WCM-ISOT 11 Probe Kit Part No: WCM-Probe Wavecom Printer Labels Part No: WCM-ZL24 (Colour) Wavecom Printer Ribbons Part No: WCM-ZRIB24 WinPATS Extended Support (12 months) Part No: WCM-WinPATS Support IEC 20amp-10amp Current Limi
Wavecom Instruments Fully Integrated Test n Print Unit User Manual SPECIFICATIONS TnP® Series Mains Supply Test Checks Polarity and continuity of mains supply by LED indicators (A-N, A-E, and N-E). (Flashing red LED indicates test fail) CLASS 1 Earthed Appliance Appliance Check: Ensures appliance is plugged in and turned on. Earth Bond Test: 200mA test current. Pass level Less than 1.0 Ω. Measurement: 0.01Ω to 10 Ω. Insulation Test: 500VDC / 250VDC. Pass level Greater than 1M Ω. Measurement: 0.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual TnP-500 (X)® Series extra features Meter Mode ® - (Independent of all other Tests) How to activate Meter Mode Hold F3 from main screen display for 2 seconds Screen will change to show volts by default when socket is ( not powered ) Plug appliance into testers , test socket , Press F3 to go into power mode and will show ( Warning device will be powered ) Press F3 again to continue and (power the device).
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Explanation of Electrical Parameters Volts A volt is the unit used to measure the energy available in the electrical current of a circuit. Voltage controls the available electrical power (wattage). Amperes An amp is the unit used to measure electrical current as it flows past a specified point. Watts A watt is the unit used to measure the amount of actual flowing electrical energy.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual WinPATS Professional Asset Management Software A Full Version of WinPATS Software is included with models TnP-500 (10A) & TnP-500X (20A). WinPATS must be installed on a Laptop or PC from the Autorun menu on the CD provided. The USB-USB Driver supplied on the CD must also be installed! *Brief Installation steps.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Disclaimer – E&OE All specifications may be subject to be change by Wavecom Pty. Ltd. without prior notice. Updated Specifications & Model changes may be found on the Wavecom website:- www.wavecom.com.au At the time of developing this manual, all care and consideration for accuracy has been implemented. Wavecom accepts no responsibility for any errors or omissions in this document.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual WAVECOM TT040-50 Thermal Transfer BARCODE Printer Please Note: there is a master POWER SWITCH at the rear r/h side of the printer. This should be left ON under all normal operation conditions. Full instructions on the operation of the BARCODE printer can be found in the Owner’s Manual located on the Main Software and Drivers CD supplied with the TnP-500 series unit.
Wavecom Instruments Fully Integrated Test n Print Unit User Manual Fully Integrated TEST n PRINT UNIT TnP-500® USER NOTES www.wavecom.com.