User manual
Wavecom Instruments Portable Appliance Testers Instruction Manual
17
Power Test - Main menu B
The Power Test is for the purposes of monitoring and performance testing up to the current value 10Amps.
Please Note: A Visual Inspection test must be carried out before any others (refer to First Test Section)
The Power TEST completes the following sequence as part of its comprehensive testing procedure:
1. Integrated Supply Mains Test
Refer to Integrated Test section
2. Power Test
Procedure:
1. Complete a Visual Inspection. For details refer to the First Test section. If the unit passed the Visual
Inspection, continue with the following instructions. If not, refer to the First Test section.
2. Plug male end of appliance into TNT - Series Appliance socket.
3. Press F1 to start the power test.
4. If the appliance is safe to test press F3 on safety warning message. The unit will power on.
5. Read and record results appropriately.
6. Once the appliance has powered down and the test is complete. Unplug the unit.
7. Press Enter to return to the main menu.
This test is ideal for service agents and electricians. The user can plug in the appliance and turn it on with real
time measurements displayed on the display. This is useful when testing an appliance with a
compliance/name plate on it. The operator can compare the name plate details of operating voltage,
operating current, and power factor etc. should the appliance exceed the said values on the name plate it
could be deemed faulty and require service.
Please note: Because the power test is not required in the electrical testing standards there is no pass / fail
value in the TnT+. It is up to the user to determine if the item is a pass or a fail based on the compliance/name
plate.
If the result was a pass - Tag with the appropriate tag including "next test due" date and "return to service".
If the result was a fail - Tag with a DANGER TAG and remove the unit from service.
The Power Test allows the user to turn the appliance on and measure its performance as a digital
wattmeter. Displayed parameters are:
Volts AC
Current
Volt Amp
Power Factor
Watts
Caution: Before operating ensure the equipment is firmly secured to eliminate the possibility of causing injury
or damage. This function turns powers the Unit on, Please make sure the drills or any blades of any rotating
devices have been removed prior to any testing and have clearance from body or object. Appliances may
jump off benches and may need to be secured by clamping them, or they may cause serious damage if not
secured properly.