Visual Inspection (First Test)
VISUAL INSPECTION IS TO OCCUR BEFORE ANY OTHER TEST IS CARRIED OUT BEFORE USING ANY
OF THE RANGE OF TnT APPLIANCE TESTERS
There is no damage or component defects to the accessories, plugs, outlet sockets or connectors
(physical).
There are no cracks &/or abrasions.
There are no exposed inner cores or conductors (flexible) and the supply cords are not twisted or
distorted.
Any Fuse / Over load protection components (if fitted) are checked.
All labels, markings and warning indicators (of the maximum load to be connected to the device) are
legible and intact.
The insulation is not damaged in any way i.e. melted, cuts or abrasions. There are no iron filings in
the insulation. There is no insulation tape on the lead.
Any flexible cords and/or leads are effectively anchored (glands and grommets intact).
All covers or guards are in place and secure as intended by the supplier/manufacturer.
All safety devices and systems are in good working order. (i.e. overload latches & buttons).
No dust &/or dirt obstructs any exhausts or ventilation outlets.
All controls are working properly and are secure and aligned.
Important: If result is a FAIL!!
If any Equipment FAILS ANY of the above, it should be deemed to have FAILED the Visual Test, and
therefore no other tests need be performed. If this is the case the Equipment should be tagged with a
DANGER TAG and removed from service. It is recommended by the manufacturer and distributor of this
product that it SHOULD NOT BE RETURNED TO SERVICE. To do so would be considered unsafe.
TNT Series (All models - Menu A)
Test Function Flow Chart
Main menu A
Main menu A
F1 Class 1 Test (Earth Test)
F2 Class 2 Test (Double Ins Test)
F3 Lead Test (Ext Lead Test)
F1 Class 1 Test (Earth Test)
Supply Mains Test
NCNT Test
Earth Bond Test
Insulation Test
Results Summary
F2 Class 2 Test (Double Ins Test)
Supply Mains Test
NCNT Test
Double Ins Test
Results Summary