Instruction manual
35
Power Test (for TnT+ model only) ___ ________
Voltage 220 – 270 VAC + < 5% of reading
Current 0 -10 A + < 5% of reading (X-Models Only, 0 – 20A)
Load current max 10A resistive
HBC fuse protected 500Vac
(X-Models Only 20A, Thermal overload protected manual reset
RCD Test (for TnT+ model only) ____ ______
Trip Current 2 – 500mA + < 5% of value
Trip Time 0 – 300 mS + < 1mS
Battery powered when testing RCD
Display (for TnT, TnT-el & TnT+ models) ____ ______
Backlit Graphics. 64 x 128 LCD PVC protected (Blue White) 40 x 70mm
Mechanical (for TnT, TnT-el & TnT+ models) __ ________
Case ABS plastic
Size: 200L x 175W x 70D
Weight: 1.5Kg (X-Models Only, 2.5Kg)
Safety (for TnT, TnT-el & TnT+ models) ____ _______
The instrument in general meets the requirements of relevant
IEC, AS & CE.
Safety Class II (Double insulated)
CAT III 600V
DUT Test Fuse Protected at 10A, only use HBC fuses, warranty void if not used
Tester Fuse Protected. 1A Non user serviceable