Instruction manual
28
Main Menu A
Earthed Test
D/Insulated Test
Ext Lead Test
If the item passes a visual inspection and pass is selected, testing can begin. Select the
correct test based on the appliance type.
Test Results
Earthbond Pass
Insulation Pass
Once test has completed the results are displayed.
What Next?
Re-Test Cont.
To test the item multiple times press (F3) this will take you back to the main menu A screen.
From here you can choose a test class. You would use this for example if testing power
boards. To complete the test press (enter). This will take you back to the new barcode screen.
If you have a zebra printer a barcode will be printed once (enter) is pressed.
Visual Check Only Option
Visual Check
xx/xx/xxxx xx:xx
Out of Services
Fail Pass
Items can be passed with a visual check only (no testing required). You must be at the visual
check screen shown on the left. To do a visual check only press and hold (enter) for 2
seconds.
Visual Check
Only?
Save and Exit
Yes No
Pressing (enter) will take you back to the visual check screen. Pressing (F3) will complete the
test. Print out a tag if you have a zebra printer. Then go back to the new barcode screen.
Retesting Equipment
The following must be done before retesting:
A site must exist in the tester with records. A site is usually uploaded from WinPATS.
The correct site must be displayed on the first line of the new / search barcode screen. If the incorrect site is displayed no equipment
will be reported when scanned. To change see the add sites section.
The correct user must be selected from the users list. A user is important because it give a reference to the test results in WinPATS.
It is also the user that is displayed on the tag. If there is no users create a users as described in the add equipment section or upload
the users list from WinPATS.
Screen
Instruction
Site x
Search Barcode
0000000 5000
Type in or scan the barcode number to be searched and press enter. If the screen displays
new barcode press enter to switch over. The screen can only be switched if there is no
numbered entered in.
Loc | Desc | Make
The existing details will be shown about the record. Any changes made here will be updated
once the site is downloaded in WinPATS. If nothing needs changing hold the enter key to
proceed to the next screen.
Visual Check
xx/xx/xxxx xx:xx
Out of Services
Fail Pass
After all item details have been entered, hold the enter key for 2 seconds to proceed to the
Visual Check screen. After the item has been visually inspected, there is 1 of 3 options that
can be selected; Out of Service (F2), Fail (F3) and Pass (enter). If Out of Services or Fail is
selected the result will be saved and the TnT will revert back to the barcode entry screen. If
you have a zebra printer a tag will be printed. If the test is a visual check only then press
(enter hold). See add equipment for details.
Main Menu A
Earthed Test
D/Insulated Test
Ext Lead Test
If the item passes a visual inspection and pass is selected, testing can begin.
Test Results
Earthbond Pass
Insulation Pass
Once test has completed the results are displayed.
What Next?
Re-Test Cont.
To test the item multiple times press (F3) this will take you back to the main menu A screen.
From here you can choose a test class. You would use this for example if testing power
boards. To complete the test press (enter). This will take you back to the search barcode
screen. If you have a zebra printer a barcode will be printed once (enter) is pressed.
To download records using WinPATS MX software, please refer to the Downloading Records section of the WinPATS manual