7 Troubleshooting
This section describes:
Problems that may be encountered when using the Integra Wireless CPU
®
Possible causes
Possible solutions
To review other troubleshooting information, refer to the 'FAQs' (Frequently Asked Questions) page either at
www.wavecom.com or use the following link:
http://www.wavecom.com/modules/movie/scenes/support/
7.1 Not Connecting Through the Serial Link
If the Wireless CPU
®
does not answer through the serial link on attempted transmission of data, refer to the
table below for possible causes and solutions:
Table 5: Solutions for no connection through the serial link
If the Wireless CPU
®
returns:
Then ask: Corrective Action:
Is the Wireless CPU
®
correctly
powered?
Provide a power supply to the
Wireless CPU
®
.
Is the serial cable correctly
connected to the Wireless CPU
®
and PC sockets?
Connect the cable.
Is the communication program
correctly configured?
Ensure the following Wireless CPU
®
settings:
Data bits = 8
Parity = none
Stop bits = 1
Baud = 9600 bps
Nothing
Is there another program
interfering with the
communication program?
Close the application in conflict on the
communication port (e.g. mouse or
printer driver)