Specifications
Integra M2106+
Erreur ! Style non défini.
©Confidential
Page: 51 / 77
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without prior written
agreement.
WA_DEV_M2106+_PTS_003-001 April, 2007
4.3.2 Power Consumption without Open AT
®
Processing
The following measurement results are relevant only when:
• There is no Open AT
®
application,
• The Open AT
®
application is disabled,
• No processing is required by the Open AT
®
application.
Power supply: 5 V DC ± 5%, 1.5 A
Operating mode Parameters
I
NOM
average
I
MAX
peak
Unit
OFF Mode
16 NA µA
Paging 9
18.2 150
RX
mA
Fast Idle Mode
Paging 2
20.4 150
RX
mA
Paging 9
10.3 150
RX
mA
Slow Idle Mode
Paging 2
13.3 150
RX
mA
Fast Standby
17 -
mA
Slow Standby
9.4 -
mA
PCL5
226 1100
TX
mA
EGSM900
PCL19
102 240
TX
mA
PCL0
158 620
TX
mA
Connected Mode
DCS1800
PCL15
99 220
TX
mA
Gamma 3
212 1100
TX
mA
EGSM900
Gamma 17
92 210
TX
mA
Gamma 3
145 590
TX
mA
Transfer Mode
Class 8 (4Rx/1Tx)
DCS1800
Gamma 18
88 190
TX
mA
Gamma 3
377 1300
TX
mA
EGSM900
Gamma 17
134 240
TX
mA
Gamma 3
242 690
TX
mA
GPRS
Transfer Mode
Class 10 (3Rx/2Tx)
DCS1800
Gamma 18
127 220
TX
mA
TX
means that the peak current is measured during a TX transmission burst
RX
means that the peak current is measured during a RX reception burst