Specifications
Product Technical Specification & Customer Design Guidelines
Consumption Measurement Procedure
© Confidential
Page: 98 / 116
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without
prior written agreement.
WA_DEV_Q64_PTS_001-003 January 9, 2009
4.3 Template
This template may be used for consumption measurement, all modes and
configurations are available.
Three VCC voltages are measured, 3.2V, 3.6V and 4.8V and the minimum/maximum
RF transmission power configurations are set and measured.
Power consumption
Operating mode Parameters
I
MIN
average
VCC=4,8V
I
NOM
average
VCC=3,6V
I
MAX
average
VCC=3,2V
I
MAX
peak
unit
Alarm Mode
µA
Paging 9 (Rx burst occurrence ~2s)
mA
Fast Idle Mode
Paging 2 (Rx burst occurrence ~0,5s)
mA
Paging 9 (Rx burst occurrence ~2s)
mA
Slow Idle Mode
Paging 2 (Rx burst occurrence ~0,5s)
mA
Fast Standby Mode
mA
Slow Standby Mode
mA
PCL5 (TX power 33dBm)
mA
850/900 MHz
PCL19 (TX power 5dBm)
mA
PCL0 (TX power 30dBm)
mA
Connected Mode
1800/1900 MHz
PCL15 (TX power 0dBm)
mA
Gam.3 (TX power
33dBm)
mA
850/900 MHz
Gam.17 (TX power
5dBm)
mA
Gam.3 (TX power
30dBm)
mA
Transfer
Mode
class 8
(4Rx/1Tx)
1800/1900 MHz
Gam.18 (TX power
0dBm)
mA
Gam.3 (TX power
33dBm)
mA
850/900 MHz
Gam.17 (TX power
5dBm)
mA
Gam.3 (TX power
30dBm)
mA
Gam.18 (TX power
0dBm)
mA
GPRS
Transfer
Mode
class 10
(3Rx/2Tx)
1800/1900 MHz
Gam.18 (TX power
0dBm)
mA