Specifications

Product Technical Specification & Customer Design Guidelines
Interfaces
© Confidential
Page: 31 / 116
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without
prior written agreement.
WA_DEV_Q64_PTS_001-003 January 9, 2009
Open drain outputs type
Signal name Parameter I/O type Minimum Typ Maximum Condition
V
OL
Open Drain
0.4V BUZZER
I
OL
Open Drain
100mA
Pull-up outputs type
Signal name Parameter I/O type Minimum Typ Maximum Condition
V
IH
Pull-up 2V
V
IL
Pull-up 0.8V
V
OL
Pull-up 0.4V
SDA /
GPIO13
and
SCL /
GPIO14
I
OL
Pull-up 3mA
SDA and SCL are internally pulled up with each 1 k resistor to voltage 2.8V (VREF)
inside the Q64 Wireless CPU
®
.
The reset states for each I/O are given in the corresponding interface chapter
descriptions. The state definitions are defined below:
Reset state definition
Parameter Definition
0
Set to GND
1
Set to supply 2V8
Pull down
Internal pull down with ~60K resistor.
Pull up Internal pull up with ~60K resistor to supply 2V8.
Z High impedance
Undefined Be careful, undefined should not be used in your application
if a special state is needed at reset. Those pins can be
toggling signals during reset.