5.1 Factory settings
The modem has the following factory settings. Please refer to the AT command document for the
meaning of each setting.
Related AT commands Factory Settings Description
AT+IPR 9600 DTE-DCE data rate
AT+IFC 2,2 DTE-DCE flow control
AT+ICF 3,4 DTE-DCE character framing
ATE 1 ECHO
AT&C 1 DCD signal
AT&D 1 DTR signal
ATQ 0 Result code suppression
ATV 1 Response format
AT&S 1 DSR signal
ATS0 0 Auto answer
AT+CLIP 0 Calling line ID presentation
AT+CRLP Calling line ID restriction
AT+CSCS “PCCP437”
AT+CMGF 1 Message format
AT+CSMP 1,67,0,0 Text mode parameters
AT+CNMI 0,0,0,0 New message indication
5.2 Input / Output port
This port can be configured as either an input one or an output one.
To configure it as an input port, first issue AT+WIOW=2, 0 to disable the output port. Use
AT+WIOR=3(Maestro 100) or AT+WIOR=1(Maestro 20) to read the status of this input port. Response
+WIOR: 0 represent Logic HIGH (>3V); Response +WIOR: 1 represent Logic LOW (<0.5V) To use it as
an output port, issue AT+WIOW=2,1 will turn it on and it will drain current to ground. The current is
recommended not to exceed 10 mA. Issue AT+WIOW=2,0 will turn it off.
5.3 RS232 AUTO-ONLINE mode (power saving)
When being in the AUTO-ONLINE, the RS232 transceiver will shutdown most of its hardware to save
power if it does not detect a valid input for more than 100uS. The RS232 transceiver will wake up when
valid input is detected again.
By default, the RS232 transceiver is put in AUTO-ONLINE. This mode can be turned off by issuing
AT+WIOW=4,1.