Figure 19: Antenna Diagnostic Circuit
The current antenna status is based on a comparison between the voltage measured at the antenna
connector and the limits set by the application for OPEN and SHORT.
Because of the tolerances associated with Wireless CPU
®
power supply, ADC power supply and the
ADC itself, there will be a correction factor in the ADC reading as listed below in
Table 25.
Lower Limit Nominal Higher Limit
ADC Reading Correction (%) -5 4 11
ADC Correction (Multiplying Factor) 0.95 1.04 1.1
Table 25: Range of ADC readings for an external antenna
Example: The multiplying factors shown above are used to establish the ADC limits values for an
antenna OPEN, SHORT and nominal conditions of a known antenna resistance value. These limits
can be calculated using the formula below:
ADC Reading = 255 * Multiplying Factor * RL/(R+ RL)
The following example shows calculation using internal resistance (R) = 49.9K and antenna
resistance (RL) = 10K.
Lower Limit of ADC Reading = 255 * 0.95 * 10k/ (49.9k + 10k) = 41
Nominal Value of ADC Reading = 255 * 1.04 * 10k/ (49.9k + 10k) = 45
Upper Limit of ADC Reading = 255 * 1.1 * 10k/ (49.9k + 10k) = 47
Note: All ADC values should be rounded up to next integer value.