Specifications
Wireless CPU
®
Q24 Series
Environmental Specifications
©Confidential Page: 71 / 83
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged without
prior written agreement.
WM_PGM_Q24NG_PTS_001-005
November 20, 2007
lifications
xtended, applied
environmental qualifications are defined in the table below:
5.1 Environmental Qua
For the Wireless CPU
®
Q24 Classic, Q24 Plus, and Q24 E
ENVIRONMENTAL CLASSES
Cold IEC 68-2.1 -25° C 72 h -40° C 72 h -20° C (GSM900) 16 h
-10° C (GSM1800/1900) 16h
Dry heat IEC 68-2.2 +70° C 72 h +70° C 72 h +55° C 16 h
Change of temperature IEC 68-2.14 -40° / +30° C 5 cycles -20° / +30° C (GSM900) 3 cycles
t1 = 3 h -10° / +30° C (GSM1800/1900):
3 h
Damp heat IEC 68-2.30 +30° C 2 cycles +40° C 2 cycles +40° C 2 cycles
cyclic Db test 90% - 100% RH 90% - 100% RH 90% - 100% RH
variant 1
ys +40° C 4 days
C
Hz : 5 mm / s
2 / s3 10 -12 Hz : 0.96 m2 / s3
Random vibration IEC 68-3.36 20 - 500Hz : - 3 dB / oct 12 - 150Hz : - 3 dB / oct
wide band Fdb test x 10 min 3 x 30 min
TYPE OF TEST STANDARDS STORAGE TRANSPORTATION OPERATING (PORT USE)
Class 1.2 Class 2.3 Class 7.3
Ab test
Bb test
Na/Nb test
3 cycles t1 =
variant 1 variant 1
Damp heat IEC 68-2.56 +30° C 4 days +40° C 4 da
b test
Sinusoidal vibration IEC 68-2.6 5 - 62
Fc test 62 - 200Hz : 2 m / s2
3 x 5 sweep cycles
5 - 20 Hz : 0.96 m
3
Figure 16: Q24 Classic, Q24 Plus and Q24 Extended Environmental classes
For more details, refer to the document "Environmental Control Plan" for Wireless
CPU
®
Q24 Series [9].
Electro-Static Discharge (ESD):
According to the EN 61000-4-2 standard, the maximum ESD level supported by the
Wireless CPU
®
series on contact discharges is ±1 kV on the 60-pin connector, ±2 kV