Specifications
WM_PRJ_Q2400_PTS_001 - 003
6th November 2002
confidential ©
Page :
57 / 70
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
6 Appendix
6.1 Wavecom acceptance test
These tests are Wavecom internal qualification tests. They are performed on a
Wavecom evaluation platform (module on test board).
Test
Applied standard Acceptance criteria
Performance
Test
ETSI recommendation for
GSM900/GSM1800 (and
GSM900/GSM1900)
communication.
Full conformity to the recommendation regarding
the main RF parameters.
Cooking Test - The test continues even after the Cooking Test
milestone has been reached
Stress Test Therma shocks IEC 68-2-14. Full conformity to the recommendation regarding
the main parameters.
Vibration Test Sinusoidal vibration IEC 68-2-6. No performance degradation or mechanical
degradation is allowed after test.
Vibration Test Random vibration IEC 68-2-36. No performance degradation or mechanical
degradation is allowed after test.
Shock Test IEC 68-2-27. No performance degradation or mechanical
degradation is allowed after test.
Bump Test IEC 68-2-29. No performance degradation or mechanical
degradation is allowed after test.
Humidity Test Corrosion test IEC 68-2-3. No visible degradation of the product, both
visual and functionnal.
The unit is tested at room temperature and must
be fully operative for the main RF parameters.
Warehouse Tet Low temperance IEC 68-2-1. Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Warehouse
Test
High temperature IEC 68-2-2. Under normal condition (room temperature) after
the test, the unit must behave in full conformity
with the main RF parameters specification.
Dust Test1 MIL-STD-810D, method 510-3. No visible dust in the visible areas. No more than
50 dust particules in the cabinet of the product.
The unit, tested at room temperature must be
fully operative.
Light Test1 UV radiation and temperature EDF
HN60E03.
Visual inspection on the discoloration and other
degradation effects such as cracks in the
material of the unit after the test.
Fall Test1 IEC 68-2-32. Only minor casing degradation is allowed, with a
maximum dimension change of 1mm. The unit
must remain fully operative and full specification
for the main RF parameters.