Specifications
WM_PRJ_Q2400_PTS_001 - 003
6th November 2002
confidential ©
Page :
34 / 70
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
2.13.1.2 Power OFF
To properly power OFF the module, the application must set the ON/OFF signal
to low and then send the AT+CPOF command to de-register from the network
and switch off the module. Once the « OK » response is issued by the module,
the power supply can be switched off.
POWER SUPPL
Y
ON
/
OFF
AT COMMAND
STATE OF THE MODULE
AT+CPOF
Module
READY
Module OFF
I
BB+RF
<100µA
Network dependent
OK res
p
onse
I
BB+RF
= overall current consumption (Base Band + RF part)
Figure 11 : Power-OFF sequence
2.14 BOOT (optional)
This input can be used to download a software in the Flash ROM of the
WISMO Quik Q2403 Series module. For the applications based on AT
commands this is a backup download procedure only (see chapter Firmware
upgrade). The internal boot procedure is started when this pin is low during
the reset of the module. In normal mode this pin has to be left open. In Internal
boot mode, low level has to be set through a 1K
Ω
resistor. If used, this input
has to be driven by an open collector or an open drain.
BOOT : Pin 12
1K
Ω
BOOT : Pin 12
1K
Ω
Switch BOOT
Figure 12 : BOOT pin connection
•
If Switch Boot = 1, Boot pin 12 = 0, for download mode
•