If the Fastrack modem returns a message of ERROR, you can have the
extended error code by using AT command
AT+CMEE=1
. Refer to the table
below for interpretation of extended error code.
Table 15:
Interpretation of extended error code
Error
Code
Diagnostic Hint
0 Phone failure Call your technical support.
3 Operation not
allowed
4 Operation not
supported
No action.
10 SIM not inserted
If SIM card is inserted, check the SIM card if it
is clean and properly inserted.
11 SIM PIN required Enter PIN code.
12 SIM PUK required Enter PUK code.
Note: Call your network provider if you don’t
know this code.
13 SIM Failure Check validity of your SIM card. If SIM card
damaged, call your network provider.
16 Incorrect password Check the code you entered.
17 SIM PIN2 required Enter PIN2 code.
18 SIM PUK2 required Enter PUK2 code (call your network provider if
you don’t know this code).
26 Dial string too long Check your phone number (max 20 digits).
30 No network service No action.
32 Network not allowed
Emergency calls only
No action.
40 Network
personalization PIN
required (Network
lock)
Enter Network lock code (call your network
provider if you don’t know this code).
103 Illegal MS (#3) No action.
106 Illegal ME (#6) No action.
107 GPRS services not
allowed (#7)
Contact your network provider to subscribe to
the GPRS services.
111 PLMN area not
allowed (#11)
No action.