Specifications
RT9 Powershelf Rectifier Technologies
158-1806-01.doc
42 2-Mar-06
Serial Number 1297-041 Software Version V03.9 (000211)
Press Enter to go into Setup Mode
4. To enter the Setup Mode, you must press Enter within 3 seconds.
*** basic parameters
Hardware: Ethernet Autodetect
IP addr 192.168.000.098, no gateway set
***************** Channel 1 *****************
Baudrate 09600, I/F Mode 4C, Flow 00
Port 10001
Remote IP Adr: --- none ---, Port 00000
Connect Mode: C0 Disconn Mode: 00
Flush Mode: 00
Change Setup : 0 Server configuration
1 Channel 1 configuration
7 Factory defaults
8 Exit without save
9 Save and exit Your choice ?
5. Select an option on the menu by entering the number of the option in the Your
choice ? field and pressing Enter.
.
6. To enter a value for a parameter, type the value and press Enter, or to confirm a
current value, just press Enter.
7. When you are finished, save the new configurations (option 9). The unit will
reboot.
7.2.4 Server Configuration (Network Configuration)
These are the unit’s basic network parameters. The following parameters are
displayed when you select login into the unit:
*** basic parameters
Hardware: Ethernet Autodetect
IP addr 192.168.000.098, no gateway set
Select 0 and press Enter to configure the Lantronix Interface Server’s basic
parameters
IP Address
The IP address must be set to a unique value in your network.
Note: Lantronix Interface cannot connect to the network if the assigned IP address
is already in use by another device.