User's Manual

Table Of Contents
. . . . .
SPECIFICATIONS
General Specifications
Hardware Installation Guide A-3
/(',1',&$7256
Figure A-2 Front Panel Indicators
Table A-2 Environment Specifications
Parameter Specification
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature –40°C to 66°C (–40°F to 150°F)
Operating Humidity
10% to 95% RH non-condensing
Storage Humidity
Elevation
200 feet (61 meters) below sea level to 13000 feet
(3943 meters) above sea level
Shock
Transportation/Handling Shock: Drop Test per NSTA
Project 2A
Operation Shock: Bellcore TR-TSY-000487, Section
5.1.4.9, Subsection IIA (Drop Tests for Unpacked
Housing Weighing 50 lb or less)
Vibration
Transportation Vibration: ASTM D 4728 Random
Vibration Testing Truck/Air Spectrum (1G, 5-200 Hz),
according to the general requirements of ASTM D
4728
Operational Vibration: Bellcore TR-TSY-000487,
Section 5.1.4.11 (Vibration Test-Low Level)
Table A-3 Front Panel Indicators
Name Color Function
32:(5
Yellow ON = power to the radio is on
6<1&
Green ON = radio receiving data frame header
564
Green
Steady illumination of LEDs indicates the strongest/highest quality of the receive
signal.
Sequential illumination of all 7 LEDs indicates radio initialization self-test is in progress.
Blinking of all 7 LEDs in addition to audible alarm indicates Configuration Reset DIP
switch is ON and that the radio initial configuration and manufacturing image are
selected for next restart.
Blinking of the 1st of the 7 LEDs in addition to audible alarm indicates the wrong RF
channel is set on the DIP switches.
Blinking of the 2nd of the 7 LEDs in addition to audible alarm indicates the wrong PN
code is set on the DIP switches.
Blinking of the 3rd of the 7 LEDs in addition to audible alarm indicates that digital
board initialization has failed.
OFF while SYNC LED is illuminated indicates that the radio is not configured.
RSQ
SYNC
POWER