HARDWARE INSTALLATION
Basic Configuration Setup
Hardware Installation Guide 3-7
See the Site Manager Reference, Chapter 8, for instructions on antenna
alignment.
COMMAND LINE INTERFACE
AirPro Gold can be configured through a command line interface
running on a terminal (or a PC running a terminal emulation program).
Before connecting the terminal to a AirPro Gold unit, configure the
terminal with the following settings:
Baud rate = 115200 bps
Data bits = 8
Parity = None
Stop bits = 1
Flow control = Hardware
If you are using a PC or laptop computer, refer to the operating system
documentation for instructions on how to configure and run the terminal
emulation program.
To set up a basic unit configuration using the command line interface:
1 Remove the unit from the shipping carton.
2 Remove the switch plate from the front of the unit. See Figure 3-4 on page 3-5.
3 Make sure ALL the DIP switches are in the OFF position. This is the
manufacturing default.
To set the switch to the OFF position, push the switch down toward the bottom
of the unit.
4 Connect the terminal or PC to the RS232 port on the front of the unit. See
Figure 3-5 on page 3-7.
Use a crossover (null modem) cable with a DB-9 male connector on one end to
connect to the unit, and an appropriate connector at the computer end.
Figure 3-5 Connecting the Terminal or PC
5 Turn on the terminal.
Ethernet
RS232
RSQ/RSSI